Products

Regional Leakage Detector

OM-LDA-B801

The OM-LDA-B801 Regional Leak Detector is designed for compatibility with the OM-LDA-B601/5/10/15 leak-sensing cables, point sensors, and normally open dry contact devices (e.g., float switches, adapted optical probes, limit switches), allowing for the monitoring of up to 500 meters of sensing cable. Ideal for conventional (non-hazardous) environments, the OM-LDA-B801 features dual LED indicators for power status and communication activity, alongside an SPDT contact relay. This leakage detector operates as a standalone leak detection and alarm unit or can integrate into a primary control system (computer or automation controls) via RS-485 serial communication over shielded twisted-pair wiring.

lPowered by 12V DC, with polarized connection required.

lAdjustable sensitivity with a seamless range.

lDual-mode relay output offering both normally open and normally closed configurations for selection at will.

lSupport for multiple communication protocols with automatic protocol selection.

lThe simple twisted-pair serial RS-485 communication can reach 1200 meters without amplification.

lOn-site audible and visual alarms for swift event pinpointing.

lIncorporates state-of-the-art electrostatic and surge protection for dependable operation.

lOffers robust and reliable real-time liquid leakage monitoring.

lAvailable enclosures cater to both independent indoor setups and complex outdoor installation requirements.

lSupports a convenient 35mm DIN rail mounting option.

lDimensions: 58 x 115 x 36 mm, as illustrated below.

Dimensional drawing of appearance

Sensor Compatibility

Works with OM-LDA-B601 water detection cables, similar types of liquid leakage cables, or probe detectors

Cable Length for Monitoring

Can connect to cable lengths up to 500 meters

Housing

Made of white PVC material

Weight

Weighs 150 grams

Accuracy Level

Rated at 100% accuracy (context-dependent)

Serial Interface

Utilizes an RS-485 dual-line configuration for networked setups

Communication Standard

Supports MODBUS protocol

Output Options for Relay

Provides both Normally Open (NO) and Normally Closed (NC) configurations

Power Supply Requirements

Needs 12V DC power supply, 3W

Capacity Ratings

Can handle AC250V, 3A, and DC30V, 3A

Temperature Conditions for Storage

Ranges from -40°C to 60°C

Operational Conditions

Functions in environments from -20°C to 50°C with a humidity range of 5% to 90% (non-condensing)

Certification Received

Certified with CE


Data center